Active and Passive Scripts that implement the getMetadata function are treated as first-class scan rules by ZAP. An example implementation of this function in a script would look like:

function getMetadata() {
	return ScanRuleMetadata.fromYaml(`
id: 12345
name: Active Vulnerability Title
description: Full description
solution: The solution
references:
  - Reference 1
  - Reference 2
category: INJECTION  # info_gather, browser, server, misc, injection
risk: INFO  # info, low, medium, high
confidence: LOW  # false_positive, low, medium, high, user_confirmed
cweId: 0
wascId: 0
alertTags:
  name1: value1
  name2: value2
otherInfo: Any other Info
status: alpha
alertRefOverrides:
  12345-1:
    name: Alert Reference 1

`);
}

The metadata function is evaluated upon saving the script, which is exposed as a scan rule if the metadata is valid.

The category field is only used for Active Scan Scripts.

The alertRefOverrides field allows you to override specific fields for each alert reference. You may override any top-level field except id, category, and status. An alert reference is used as a unique identifier for an alert type when a scan rule may raise more than one type of alert. Typically, alert references for a given scan rule are expected to be equal to the scan rule ID suffixed with sequential digits, e.g. 12345-1, 12345-2, etc. To raise an alert that uses the metadata for a given alert reference, you may pass the alert reference as an argument to newAlert().

Any undefined fields in the metadata are ignored (e.g. author: your name).